TS Lightning Protection Co.,Limited

Start Future From Safety

NO LIGHTNING ACCIDENT IS ALLOWED

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsVoltage Surge Suppressor

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

  • Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v
  • Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v
  • Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v
  • Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v
Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v
Product Details:
Place of Origin: Guangdong,China
Brand Name: TSTLP
Certification: CE Compliance
Model Number: TS-230M5RM
Payment & Shipping Terms:
Minimum Order Quantity: Negotiable
Price: Negotiable if good quantity
Packaging Details: By standard export box/carton
Delivery Time: Around 7 working days upon receipt of payment
Payment Terms: 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead
Supply Ability: 2000 sets/month
Contact Now
Detailed Product Description
Un: 230V Uc Optional: 30V / 60V / 75V / 150V / 320V
Normal Discharge Current: 5kA Type Of Remote Signalling Contact: Break Contact
Test Standards: IEC 61643-11 Certified: CE
High Light:

transient surge suppressor

,

3 phase surge suppressor

24v / 48v / 60v / 120v / 220v / 230v Type 3 Transient Surge Suppressor

 

TS-230M5RM Class III transient surge suppressor is designed as per IEC 61643-11 to install at LPZ 1-2 or higher as fine protection for electronic devices. e.g. icebox, air conditioner, photocopy, communication equipment, network equipment... various power supply system

 

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v 0

 

Relative 150Vdc / 600Vdc / 750Vdc / 1000V DC Surge Protection Device for photovolatic protection.

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v 1

 

  • Type 3 Surge Protector Technical Data
Model No. TS-230M5RM TS-120M5RM TS-60M5RM TS-48M2RM TS-24M2RM
Normal a.c. Voltage Un 230V 120V 60V 48V 24V
Rated voltage (max.a.c. continuous voltage) Uc 320V 150V 75V 60V 30V
Rated voltage (max.d.c. continuous voltage) Uc 320V 150V 75V 60V 30V
Normal Current IL 16A 16A 16A 16A 16A
Nominal discharge current (8/20, L-N) In 3 kA 2.5 kA 2.5 kA 1 kA 1 kA
Nominal discharge current (8/20, L+N-PE) In 5 kA 5 kA 5 kA 2 kA 2 kA
Combination wave (L-N) Uoc 6 kV 6 kV 6 kV 2 kV 2 kV
Combination wave (L+N-PE) Uoc 10 kV 10 kV 10 kV 4 kV 4 kV
Voltage protection level(L-N) Up ≤1.15 kV ≤0.7 kV ≤0.5 kV ≤0.35 kV ≤0.2 kV
Voltage protection level(L+N-PE) Up ≤1.5 kV ≤1.1 kV ≤0.85 kV ≤0.85 kV ≤0.85 kV
Response time tA ≤25ns (L-N); ≤100ns(L+N-PE)
Max. back up fuse 16A gL/gG
Operating temperature range Tu -40°C...+80°C
Short-circuit withstand capability at max.backup fuse 6kArms
Relative humidity: ≤95% (25°C)
Cross-sectional area 0.5mm2 ~ 6mm2 solid / 4mm2 flexible
Mounting on 35mm2 DIN rail
Enclosure material Red thermoplastic, UL94-V0
Standards IEC 61643-11; GB 18802.1; YD/T 1235.1
Type of remote signalling contact Break contact
Switching capacity UN/IN AC:250V/0.5A DC:250V/0.1A,125V/0.2A,75V/0.5A
Cross-sectional area for remote signalling contact Max. 1.5mm2 solid / flexible
Compliance CE (LVD, EMC)

 

  • Main Character
  1. Class 3 transient surge suppressor with LIGHT indications: Green - OK, red - Fault
  2. Single-phase surge protection and with disconnector
  3. Remote signalling connector for fault indication
  • INSTALLATION STEPS
  1. Mount the transient surge suppressor on 35 mm DIN rail.
  2. Connect conductors, the cross-sectional area of cable must be larger than 4mm2 . The withstand voltage value of cable is not smaller than AC500V; ensure wiring reliable.
  3. If Remote Alarm needed, it s/b connected signal lines to remote signal terminal 1 and 2 connected.
  4. After above, switch on the power supply and turn on the circuit breaker, if the transient surge suppressor’s indicator light displays green,this indicates the unit is operating normally.

Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the transient surge suppressor's indicator light displays red, electrician should check/replace the transient surge suppressor.

 

  • Installation Diagram

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v 2

 

  • Real Type 3 Surge Protection Device Installation

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v 3

 

PDF Catalog Download - TSTLP 24~230V Type 3 SPD.pd...

 

Tag: transient surge suppressor

Contact Details
TS Lightning Protection Co.,Limited

Contact Person: Franklin

Tel: +86-13926098193

Fax: 86-20-28819702-27806

Send your inquiry directly to us (0 / 3000)